Trial Radar AI | ||
|---|---|---|
De klinische studie NCT05603026 (MRI-TAVR) voor Aortaklepstenose is recruterend. Bekijk de kaartweergave van de Klinische Studies Radar en de AI-ontdekkingstools voor alle details. Of stel hier een vraag. | ||
MRI in Transcatheter Aortic Valve Replacement Patients (MRI-TAVR)
Currently, there are different TAVR valves are commercially available in the United States. The Sapien 3 valve (Edwards Lifesciences, Irvine, CA) is an annular, balloon expandable valve (BEV) and the Evolut PRO+ valve features a supra-annular design and is a SEV. A recent study utilizing resting echocardiogram demonstrated better hemodynamics of supra-annular SEV compared with BEV, mostly in patients with smaller annuli.
Cardiac magnetic resonance (CMR) has emerged as an important tool in the non-invasive assessment of patients with valvular heart disease. While CMR has been used for the diagnosis and quantification of valvular heart disease, there is a paucity of data on its use for the assessment of valvular hemodynamics in the post TAVR setting. Furthermore, it would be of utmost importance to understand how these devices perform during exertion. Of note, cardiac magnetic resonance techniques permit quantification of the myocardial extracellular volume fraction (ECV), representing a surrogate marker of reactive interstitial fibrosis, and late gadolinium enhancement (LGE), representing replacement fibrosis or scar. ECV and LGE have been independently linked with heart failure (HF) events.
Several studies have demonstrated that non-invasive CMR can be used to calculate non-invasive pressure-volume loops using cine imaging and non-invasive brachial blood pressure. This enables assessment of myocardial performance beyond LVEF. CMR-derived myocardial stroke work is a novel method allowing non-invasive assessment of total active myocardial performance, including both constructive and wasted myocardial work. Specifically, changes in LV stroke work have been shown to carry important prognostic information following TAVR.
Hypothesis The hypothesis is that SEV result in superior valvular hemodynamics (more pronounced during exercise) and exercise capacity relative to BEV. Furthermore, the hypothesis is that stress CMR will be able to demonstrate differences in these hemodynamic parameters. CMR will also provide refined assessment of paravalvular leak and its impact on ventricular function and on clinical outcomes.
STUDY DESIGN
Study Population There will be enrolled prospectively and retrospectively patients who have undergone TAVR at University Hospitals Cleveland Medical Center with different commercially available transcatheter valves and different sizes. It will then be screened all patients undergoing TAVR for a total of 90 patients.
All patients referred for TAVR will be considered for enrollment provided they meet the following inclusion and exclusion criteria. Inclusion criteria include all of the following: 1) Aortic valve stenosis with clinical indication for valve replacement decided by a dedicated heart team; 2) Planned transfemoral TAVR; 3) 18 years of age or older; 4) Able to give informed consent.
Exclusion criteria will include: 1) Patients with permanent pacemakers or implantable defibrillators; 2) Patients with non-MRI safe implants; 3) Severe claustrophobia; 4) Inability or contraindication to perform exercise bike stress test; 5) Arrhythmia which would prevent adequate cardiac gating, including atrial fibrillation; 6) Reduced left ventricular systolic function (<40%); 7) History of surgical aortic valve replacement or patients who undergo a valve-in-valve TAVR procedures; 8) Significant non-treated coronary artery disease.
Primary and Secondary Outcomes The co-primary endpoints will be analysed at 1-year follow up and will consist in: change in effective orifice area (EOA), mean gradient and peak gradient over time between valve types; and left ventricular stroke work.
Secondary outcomes will include: myocardial fibrosis; myocardial extra-cellular volume fraction; ability to perform stress CMR studies in post TAVR patient population, exercise capacity post TAVR, echocardiographic measures of valve and heart function, standard clinical outcomes of morbidity and mortality associated with TAVR.
Patient Enrollment, Treatment, and Follow-up Patients will be screened for inclusion/exclusion criteria as part of their pre-TAVR clinical evaluation. We will screen all patients undergoing TAVR for a total of 90 patients. There will be enrolled 45 patients to undergo TAVR and receive Sapien 3 BEV with two sizes (23 mm and 26 mm) and 45 patients to undergo TAVR with Evolut FX SEV in two available sizes (26 mm and 29 mm). All patients will be required to sign an informed consent. The choice for TAVR valve will be at the operator's discretion. Patients will be seen at 7- and 30-days post TAVR per routine clinical practice.
Baseline clinical parameters, procedural variables and the occurrence of MACE and bleeding events will be determined by history and corroborated by examining relevant medical records.
Transthoracic echocardiography will be performed immediately post TAVR, 1-day post TAVR and again at 30-days post TAVR as per standard clinical protocol. Patients will be treated with aspirin 81 mg daily and clopidogrel 75 mg daily for a minimum of 3 months, followed by aspirin 81 mg daily indefinitely thereafter.
MRI Imaging Protocol The first CMR will be performed up to three months prior to the TAVR procedure. Secondly, a stress CMR study will be performed 30-days (up to three months) post TAVR. Patients will have their EOA, valvular regurgitation, LV function, mean pressure gradient and peak pressure gradient assessed by standard MRI protocols. Patients will undergo an exercise stress MRI to assess exercise capacity, valve hemodynamics under stress and differences in hemodynamics between valve types. Finally, a follow up CMR will be performed 1-year after the TAVR, where it will be evaluated myocardial extracellular volume fraction and replacement fibrosis/scar in addition to the variables previously described.
CMR-Derived Non-invasive LV Pressure-Volume Loops It will be the able to calculate non-invasive pressure-volume loops using cine imaging and non-invasive brachial blood pressure. LVPV loops are derived non-invasively with ventricular-volume, heart rate and brachial pressure as inputs. LV stroke work is derived from the area of the generated pressure-volume loop.
MRI Stress Protocol The exercise MRI test will be performed on an MRI-compatible supine cycle ergometer that will be attached to the end of the MRI bed. Patients will be positioned on the gentry with a molding pad placed beneath them to help maintain patient position on the table during exercise for pre- and post-exercise scans. After initial imaging, the patient will remain supine on the table to complete the symptom-limited exercise stress test. Heart rate and blood pressure will be monitored continuously throughout exercise and during post-exercise scans. Immediately post-exercise, the patient will be placed back in the scanner for post-exercise.
Patient Safety Patients will be monitored for adverse events (AE) and serious adverse events (SAE). A data safety and monitoring board will be appointed to oversee and adjudicate these events. An AE is the development of an undesirable medical condition or the deterioration of a pre-existing medical condition following or during exposure to a pharmaceutical product, whether or not considered causally related to the product. Patients undergoing MRI and stress CMR will be screened for relevant contraindications by the research team at the time of their scan. SAE is an AE that results in death, requires in-patient hospitalization or prolongation of existing hospitalization, results in persistent or significant disability, results in a congenital abnormality or birth defect, or is an important medical event that may jeopardize the subject or may require medic...
Toon meerComparison of Hemodynamic Performance of Transcatheter Aortic Valve Replacement With Supra-Annular Self-Expanding Versus Balloon-Expandable Valves Assessed by Exercise Cardiovascular Magnetic Resonance
- MRI-TAVR
- STUDY20200834
aortic stenosis
cardiac magnetic resonance
exercise cardiovascular magnetic resonance
magnetic resonance imaging
self-expanding valve
balloon-expandable valve
aortic bioprosthesis
| Deelnemersgroep/Studiearm | Interventie/Behandeling |
|---|---|
Actieve comparatorTAVR using the self-expanding valve Evolut FX Transcatheter aortic valve replacement (TAVR) using the bioprosthesis Medtronic Evolut FX supra-annular self-expanding valve | Self-expanding Valve (Medtronic Evolut FX) Bioprothesis Medtronic Evolut FX supra-annular self-expanding valve |
Actieve comparatorTAVR using the balloon-expandable valve Sapien 3 Ultra Transcatheter aortic valve replacement (TAVR) using the bioprosthesis Edwards Sapien 3 Ultra valve | Balloon-expanding Valve (Edwards Sapien 3 Ultra) Bioprosthesis Edwards Sapien 3 Ultra valve |
| Uitkomstmaat | Beschrijving van de uitkomstmaat | Tijdsbestek |
|---|---|---|
Effective orifice area (EOA) | Change in effective orifice area (EOA) assessed by CMR between baseline and 1-year follow up (cm2) | Baseline, 30-days and 1-year |
Mean gradient | Mean AV gradient assessed by CMR (mmHg) | 1-year |
Peak gradient | Mean AV gradient assessed by CMR (mmHg) | 1-year |
| Uitkomstmaat | Beschrijving van de uitkomstmaat | Tijdsbestek |
|---|---|---|
Myocardial fibrosis | Myocardial fibrosis assessed by CMR (grams) | 1-year |
Myocardial extra-cellular volume fraction | Myocardial extra-cellular volume fraction assessed by CMR (Liters) | 1-year |
Stress CMR feasibility | Ability to perform stress CMR studies in post TAVR patient population (yes or no) | 30-days |
Exercise capacity post TAVR | Exercise capacity post TAVR assessed by CMR (METs) | 30-days |
Mean gradient by echo | Mean gradient assessed by transthoracic echocardiography (mmHg) | 1-year |
EOA by echo | Effective orifice area assessed by transthoracic echocardiography (cm2) | 1-year |
Ejection fraction by echo | Left ventricle ejection fraction assessed by transthoracic echocardiography (%) | 1-year |
Composite of morbidity and mortality associated with TAVR | Number of composite outcomes of morbidity and mortality associated with TAVR (number) | 1-year |
- Aortic valve stenosis with clinical indication for valve replacement decided by a dedicated heart team;
- Planned transfemoral TAVR; 18 years of age or older;
- Able to give informed consent.
- Patients with permanent pacemakers or implantable defibrillators;
- Patients with non-MRI safe implants;
- Severe claustrophobia;
- Inability or contraindication to perform exercise bike stress test;
- Arrhythmia which would prevent adequate cardiac gating, including atrial fibrillation;
- Reduced left ventricular systolic function (<40%);
- History of surgical aortic valve replacement or patients who undergo a valve-in-valve TAVR procedures;
- Significant non-treated coronary artery disease.
Ohio